Features
- Ready to test in 15 seconds and run all day with long 12-hour battery life
- Test up to four wavelengths with a single unit
- SC-APC connector interface
- High resolution and high dynamic range
- Enhanced macrobend detection at 1625 nm
- Optimised for Verifying PON Splitters Up to 1 × 128 Count
- Rugged, sealed design provides years of service in the most challenging environments
- Large 8-inch enhanced display for easy viewing of results indoors or outdoors
- New Fiber Visualizer feature for easy graphical summary and PDF reporting
- Verify connector quality with optional connector inspection microscope (available from AusOptic)
Easy to use for everyone, User friendly operation
The ACCESS Master MT9085 series keeps the userful rotary knob and hard-key operations of previous models while adding a large 8-inch, wide, touchscreen LCD for intuitive OTDR operations. Using the Fiber Visualizer functions with at-a-glance Pass/Fail measurement results evaluation supports efficient optical fiber I&M by both experienced and first-time field engineers.
Useful combination Touchscreen, Rotary Knob and Hard Key
The ACCESS Master MT9085 series is operated using the built-in, wide, 8-inch touchscreen, rotary knob and dedicated hard keys. The latter two are especially useful for analysis using the 2-point and LSA (4-point) methods requiring manual operations described in job specifications. On the other hand, measurement results can be saved easily just by touching the screen and inputting the file name. And the pressure-sensitive touchscreen even supports input without removing work gloves.
At-a-Glance Understanding with Fiber Visualizer Evaluation Functions
The Fiber Visualizer functions display fiber events (far end, PON splitters, optical connectors, splices, etc.) as an easy-to-understand schematic using icons and Pass/Fail evaluation results. Event measurement contents are displayed by touching each icon, making optical fiber I&M work easy even for first-time field engineers.


On selecting a red icon (indicating a threshold has been exceeded) and click the"?". A description will appear with details of possible causes of the fault.
Fiber Visualizer automatically sets the optimal measurement conditions for accurate event detection and loss analysis.
Three measurement functions on one display
MT9085 series can be used without switching screen for OTDR, Visual Light Source Test, and Optical power meter.
Easy Results Input and Saving
The MT9085 series has a matrix file name input function for pre-registering many different keywords, making it easy to input file names using a few touches and helping prevent file name errors.
Selecting the report formats.
Usually, measured results must be presented in an easy-to-read report format. In addition to saving measurement results, the MT9085 series can capture screens and create PDF-format reports without requiring a PC. Additionally, results can be shared with PCs via WLAN, Bluetooth, and USB memory interfaces. Specialist PC software tools can also be used for more detailed back-office waveform analysis and reporting, based on measured results.
Excellent OTDR Operability
Accurate Event Detection
Key OTDR function are excellent short dead zone of ≤0.8 m and high dynamic range of 46 dB, supporting measurements ranging from short fibers of a few meters to long-distance fibers of more than 200 km. The superior OTDR performance coupled with a unique Anritsu detection algorithm enables high-accuracy detection of events, and loss and reflection attenuation measurements.


Realtime Measurements Using Two Sweep Modes
MT9085 series has two modes: a high-speed sweep mode, which detects the deflection generated in a short period of time (Minimum 0.2 seconds) of an optical fiber, and a high-SNR sweeping mode, which allows real-time waveform confirmation while suppressing noise. This allows the optical fiber to instantly detect slight bending loss.


Optimized for Verifying PON Splitters Up to 1 × 128 Count
Many OTDRs claim to be able to test splitter-based, passive optical networks (PON) but the MT9085 delivers in a way others wish they could. With its high dynamic range and quick data acquisition, the MT9085 provides unparalleled resolution of single or closely spaced, cascaded splitters up to an industry-leading 1 × 128 count.
Other functions include:
- Multicore Fiber Measurement
- Bi-Directonal Measurement
- Optical Communications Check Function
- Save Data for Up To 50,0000 Waveforms
Field engineers are supported by a full range of powerful functions.
Optical Fiber I&M for Every Application
From Core and Metro Networks to Mobile, FTTH, and Data Centers
Optical fiber is used for most wired networks and many new optical fiber circuits are being installed, especially for mobile networks and between data centers (DCI).
Using the MT9085 series simplifies this I&M work.
Optical Fiber Evaluation
Generally, optical fiber lines are evaluated using Fiber-end inspection, and optical power/loss and OTDR measurements. The all-in-one MT9085 series supports all these tests.
Optical Fiber End-face Inspection


Optical power/ Loss Measurement

OTDR Measurement

Visual Light Source Test

Specifications
| Manufacturer | Anritsu |
| Comp - Model | Anritsu MT9085C |
| Model Grouping | Anritsu MT9085A/B/C Access Master |
| Compatible / Alternative SKU | MT9083A2,MT9083B2,MT9083C2 |
| Type | OTDRs |
| Comp - Calibrated or applicable wavelengths | 1310 / 1550 / 1625 nm |
| Case included? | Soft case |
| Dynamic Range | 44 — 46 dB |
| Fiber Types | Singlemode 9/125μm (OS1, OS2) (ITU-T G.652) |